Ethylene oxide sterilizer manufacturer

EO sterilizer.Made In China

Sterilizer instructions
Contact us

Mail: jacky@hnbocon.com

Contacts: Jacky Jiang

Whatsapp/WeChat:

0086 18258800889

FAX: 0086 371 55951125

ADD: 51 Xiasha 22nd Street, Hangzhou, China

Sterilizer instructions

    Large scale ethylene oxide sterilizer: it is generally used for the sterilization of a large number of processed articles.Medium sized EO sterilizer.

  • Which of the following factors influence ethylene oxide ster

    Which of the following factors influence ethylene oxide ster

    Five factors affecting the sterilization of ethylene oxide: temperature, pressure, humidity, ethylene oxide concentration and sterilization time 1、 Temperature The conventional limit of temperature is usually 37 ℃ ~ 63 ℃, and the suit...
  • Which of the following factors influence ETO sterilization

    Which of the following factors influence ETO sterilization

    The factors that affect the sterilization effect are temperature, humidity, concentration, time, pressure, packaging method, etc. 1. Temperature: The conventional limit of temperature is generally 44 ℃ ~ 56 ℃, and the most commonly used temperatu...
  • Methods to reduce EO residue

    Methods to reduce EO residue

    The method of reducing EO residue should be established to make the sterilized products meet the requirements of iso10993-7. It is necessary to control EO residue in medical devices after EO processing by proper ventilation. It is important to consid...
  • The characteristics of the eo sterilizer

    The characteristics of the eo sterilizer

    The characteristics of the eo sterilizer 1.operation process by PLC+ industrial computer automatic control, built-in high precision sensor and anti-interference system, circuit detection of temperature, relative humidity, pressure, and set the value...
  • 6 cubic meters medical EO sterilizer

    6 cubic meters medical EO sterilizer

    6 cubic meters medical EO sterilizer Advanced Modele Standard Components cabinet volume 6m cabinet size inside:Length x Width x Height =2600*1350*1700 overall size outer:Length x Width x Height =3200*2100*2300 Chamber pressure range design pressu...
  • Is sterility test required for mask

    Is sterility test required for mask

    Q:Is sterility test required for mask? A:Not necessarily. According to the international practice, that is to say, the European Union or the United States generally do not need to carry out sterility test of products. As long as the sterilization is...
  • Introduction of EO sterilizer equipment sterilization proces

    Introduction of EO sterilizer equipment sterilization proces

    The laboratory is equipped with a 100 level clean operation platform, a 10000 level sterile test and purification room, a bi incubator, and a gas chromatograph for EO / ECH analysis and test. Biological indicator (BI) test; product sterility test; et...
  • Maintenance of sterilizer

    Maintenance of sterilizer

    Maintenance of sterilizer equipment Preventive maintenance shall be planned and implemented in accordance with documented procedures. Procedures shall be documented and maintenance personnel shall be trained. Only after all specified maintenance tasks...
  • Sterilizer safety operation procedures

    Sterilizer safety operation procedures

    1. Strictly in accordance with the equipment regular maintenance and correct execution. 2. Strictly in accordance with the instructions on the use of the correct equipment operation and maintenance. 3. ETO workshop must be equipped with fire fighting...
  • Ethylene oxide sterilizer price

    Ethylene oxide sterilizer price

    Concept of sterilization The process of making a product free of any type of viable microorganism. That is to use physical and chemical methods to kill all microorganisms on the transmission medium and make it sterile. Essential for ease of use Adopt...
  • Ethylene oxide sterilization equipment

    Ethylene oxide sterilization equipment

    Use ETOgas sterilizer ETO is used in medical facilities to sterilize critical (sometimes semi critical) items that are sensitive to water or heat and cannot be steam sterilized. The medical service provider should improve the efficiency and safety of...
  • EO history and achievements

    EO history and achievements

    E.O history More than 30 years ago, this technology was developed for the sterilization of heat and humidity sensitive materials. It is the best choice for sterilization of surgical precision medical devices, optical instruments, electronic...
  • EO sterilization

    EO sterilization

    EO gas and its mixture is an effective disinfectant mainly used for sterilization of medical devices which are sensitive to damp heat but can not be sterilized with damp heat. EO is toxic, flammable and explosive. It should be noted that. Ventilation...
  • ethylene oxide gas sterilization

    ethylene oxide gas sterilization

    This product is an EO sterilizer with simple operation and convenient use, which ensures the process flow and normal operation time. Ergonomic display has an intuitive human-machine interface, preset a number of common processes, make it easy to use,...
  • Application scope of ethylene oxide sterilization

    Application scope of ethylene oxide sterilization

    Application scope of ethylene oxide sterilization Ethylene oxide does not damage the sterilized articles and has strong penetration, so most articles that are not suitable for general sterilization can be sterilized and sterilized with ethy...
  • Equipment maintenance matters needing attention

    Equipment maintenance matters needing attention

    Equipment maintenance matters needing attention Check the water level in the tank must reach the upper limit, so as not to damage the heating element Check for adequate water in steam generator, otherwise it will affect the service life Check the cir...
  • Description of ethylene oxide sterilization

    Description of ethylene oxide sterilization

    The mode of action of ethylene oxide sterilization, the penetrating ability of eto sterilization, the technological parameters of EO sterilization, the advantages and disadvantages of EtO sterilization and its cost are discussed....
  • How long does ethylene oxide sterilization take

    How long does ethylene oxide sterilization take

    Sterilization mechanism of ethylene oxide Ethylene oxide can effectively kill all kinds of microorganisms. The main mechanism of its sterilization is that EO can react with carboxyl (- COOH), amino (- NH3), hydroxy (- OH) on protein, which...
  • Why use ethylene oxide sterilization cabinet

    Why use ethylene oxide sterilization cabinet

    Why use ethylene oxide sterilization cabinet? In hospitals,health centers and other places, ethylene oxide sterilization cabinets are often used to sterilize articles. We know that there are many kinds of sterilization equipment in medical research,...
  • Inspection of mask after sterilization with EO

    Inspection of mask after sterilization with EO

    Inspection of mask after sterilization with EO Any product must pass the sterilization verification procedure to determine the sterilization process! Sterilization verification is generally carried out by half cycle method. This method is to determin...
  • How do you decontaminate a gas mask

    How do you decontaminate a gas mask

    Environmental pretreatment At present, most of the EO sterilization process starts from the requirements of products outside the sterilization room, such as masks and medical masks. Pretreatment is generally carried out in a specially designed room t...
  • How to sterilize masks with eto sterilizer

    How to sterilize masks with eto sterilizer

    Technical characteristics of ethylene oxide sterilizer Ethylene oxide sterilizer is a kind of anti-virus and sterilization product. It is a kind of equipment using ethylene oxide for sterilization, so it has strict requirements for application and ma...
  • Ethylene oxide sterilizer manufacturers in China

    Ethylene oxide sterilizer manufacturers in China

    In order to perform the EO process 100% safely, at least 97% of the air must be removed from the chamber. Today, the two most common ways to meet this requirement are (1) a deep vacuum, or (2) a series of partial vacuums, followed by a series of nitr...
  • Installation area of ethylene oxide sterilizer requirements

    Installation area of ethylene oxide sterilizer requirements

    Installation area of ethylene oxide sterilizer requirements site 1. the sterilizer should be placed in a separate room. 2. ethylene oxide sterilization site should stay away from the crowd, scene within 50 meters prohibited open flame fire operation...